Design, manufacturing, delivery, installation and commissioning of a cryogenic supply system to supply liquid hydrogen from a tank to up to four (4) test positions.
• Pipeline Types:
o Cryogenic Pipeline: Vacuum-insulated, DN40 PN16, approx. 110m in length
o Cryogenic Transfer Pipeline (optional): Vacuum-insulated, DN25 PN16, approx. 120m in length
o Cryogenic Exhaust Pipeline to Flare: Non-insulated, DN250 PN16, approx. 110m in length
o Cryogenic Distribution Panel: Vacuum-insulated, primarily DN40 PN16, central distribution panel with purge functions and flow measurement
o 3 (+1 optional) Panels at the Test Position: Vacuum-insulated, primarily DN40 PN16, compact panel with purge function and shut-off at the test site
o Purge Lines for Helium and Nitrogen: Extending up to the panel boundary
• Scope of Work (incl. but not limited to):
o Detailed, execution, and installation planning (P&IDs are available)
o Pipeline design & stress analysis, including support system design
o Panel design
o Procurement of all components
o On-site installation
o Coordination with other project lots
• Services Provided by the Client:
o Foundations
o Control system and control pressure supply
o Main pipe routes, including posts and pipe bridges for routing (excluding pipeline hangers)